
Senior Inspector - Quality (Electrical, Instrumentation & Telecom)
- Pasir Gudang, Johor
- Tetap
- Sepenuh masa
- Conduct cable glanding training, assess and approve cable glanding/termination personnel qualification.
- Review and approve cable jointer/terminator qualification certificates.
- Inspection/testing of temporary electrical works, connections to camp facilities as and when required.
- Inspect installation of supports prior to cable tray installation.
- Inspection of cable tray/conduit installation prior to release for cable laying.
- Inspect cable trench for dimensions and sand bedding prior to cable laying and prior to release each layer of cables.
- Monitor cable jointing/termination process to ensure manufacturer's recommendations are followed.
- Inspect cable glanding ,termination, dressing etc.
- Witness Insulation Resistance/continuity test of cables on the drum, after laying, prior to trench back filling and after termination.
- Witness Hi-pot test of cables.
- Surveillance during installation of equipment at substation to ensure manufacturer's recommendations are followed.
- Monitor preservation activities of switch gears, transformers, bus ducts and other equipment.
- Inspection of switch gear installation for alignment, location etc.
- Witness various testing of switchgears including IR, Hi-pot, ductor, operational etc.
- Witness various electrical tests as per applicable ITP/vendor docs.
- Final inspection of transformers, Switchgears, MCCs and other equipment's.
- Inspect underground earth cable installation, cad weld joints etc. prior to trench back filling.
- Witness earth loop resistance/ continuity test.
- Inspection of lightning protection system of each building.
- Inspect site routed lighting cable tray installation and release for cable laying.
- Inspect installation of distribution boards.
- Monitor preservation activities of motors throughout project period.
- Witness IR test and /or polarization index test etc as applicable.
- Inspect installation of local control stations.
- Witness functional test from local control station to Substation, if applicable.
- Witness various inspection/testing related to CP system prior to backfilling and after back filling.
- Inspect installation of heat tracing circuits and associated components.
- Witness inspection/testing related to overhead power distribution/transmission lines.
- Inspect each instrument against data sheet prior to release to site for installation.
- Witness calibration of each instrument as required by ITP/ specifications.
- Monitor preservation requirements of instruments and control panels.
- Inspect installation/hook up and pressure test of impulse tubing.
- Surveillance during installation of equipment at control room to ensure manufacturer's recommendations are followed.
- Inspect installation of various cables including system cables.
- Inspect installation of various F&G instruments, control panels.
- Witness testing of the F&G circuits and system as applicable.
- Witness testing of control panels.
- Verify all inspections related each loop components have been carried out as per applicable ITP's and documented.
- Witness loop continuity checking.
- Perform initial detailed inspection of certified electrical equipment based on latest IEC 60079-17 table 1,2,3 and IEC 60079-14, or perform visual or close inspection as applicable.
- Correct interpretation of equipment labels, IP Rating etc.
- Verify IP Rating is maintained.
- Should have 3 - 5 years of supervisory level experience in oil & gas platform or wind energy (HVDC/ HVAC) Platform EIT Inspection activities.
- Should have previously worked with major EPC contractors or their subcontractors.
- For Hazardous Area Electrical Inspections: Should be an experienced person whose training has included instructions on various types of protection and installation practices, IEC 60079-17 and IEC 60079-14.
- Shall possess IECEx CoPC & CompEx or ATEX certification.